{"id":768,"date":"2026-11-12T09:23:14","date_gmt":"2026-11-12T01:23:14","guid":{"rendered":"http:\/\/www.deltafms.com\/blog\/?p=768"},"modified":"2026-11-12T09:23:14","modified_gmt":"2026-11-12T01:23:14","slug":"how-to-perform-ultrasonic-disaggregation-for-particle-size-analysis-4ff4-2566ff","status":"publish","type":"post","link":"http:\/\/www.deltafms.com\/blog\/2026\/11\/12\/how-to-perform-ultrasonic-disaggregation-for-particle-size-analysis-4ff4-2566ff\/","title":{"rendered":"How to perform ultrasonic disaggregation for particle size analysis?"},"content":{"rendered":"<p>If you\u2019re deep in the particle size analysis game, you know that sample prep is 90% of accurate results\u2014nothing tanks a test faster than clumps or agglomerates throwing off your numbers. That\u2019s where ultrasonic disaggregation comes in, and as someone on the ground at an ultrasonic disaggregation supplier, I\u2019ve seen first-hand how getting this right can make or break your data. Let\u2019s break this down like we would over a coffee, no stuffy lab jargon to muddle things up. <a href=\"https:\/\/www.fycgsonic.com\/ultrasonic-sonochemistry-machine\/ultrasonic-disaggregation\/\">Ultrasonic Disaggregation<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.fycgsonic.com\/uploads\/201815823\/small\/ultrasonic-rubber-cutting-machine44297715050.jpg\"><\/p>\n<p>First, let\u2019s clear up what ultrasonic disaggregation actually is. It\u2019s not some vague \u201cmixing trick\u201d\u2014it uses high-frequency sound waves (usually 20 kHz to 40 kHz, depending on your setup) to blast apart soft, reversible agglomerates (like wet clay or powdered pigments stuck together in slurry) without damaging the actual individual particles. Unlike harsh mechanical methods (think stirring with a metal rod or high-shear mixing that can break particles), ultrasound targets the weak points where tiny particles cling, leaving your primary particles intact. That\u2019s the big win for particle size analysis\u2014you\u2019re measuring what\u2019s really there, not a clump of 5 10-micron particles looking like one 50-micron blob.<\/p>\n<p>Now, let\u2019s talk about when you\u2019d actually need this. If you\u2019re working with ceramic powders, battery materials, or even food powders (say, cocoa or flour) that clump when exposed to moisture, this is your solution. If your laser diffraction (the most common particle size method) keeps giving you a D50 that\u2019s way higher than your manufacturer specs, 9 times out of 10, it\u2019s not bad data\u2014it\u2019s bad sample prep. We\u2019ve had customers send us laser results with D50s 30% off the expected value, run a quick ultrasonic disaggregation step, and watch that number snap right into place. That\u2019s the \u201caha\u201d moment every lab tech lives for.<\/p>\n<p>But here\u2019s the thing: ultrasonic disaggregation isn\u2019t \u201cset it and forget it.\u201d Mess up the parameters, and you\u2019ll either not break enough clumps (wasted time) or break too much (ruin your particle size data). Let\u2019s walk through the step-by-step we recommend to our customers, tailored to get consistent, reliable results every single time.<\/p>\n<p>First step: Prepping your sample and dispersant. Don\u2019t just dump dry powder into water\u2014most powders don\u2019t like to stick to liquid at first, so a tiny bit of dispersant goes a long way. We\u2019re not talking industrial-grade stuff here; 0.1% to 0.5% by weight of a mild dispersant (like sodium hexametaphosphate for ceramics, or a non-ionic surfactant for organic materials) is perfect. Skip the harsh dispersants\u2014they can coat particles and skew results. Also, don\u2019t use tap water; mineral ions in tap can cause particles to flocculate (clump right back up) before you even turn on the ultrasound. Deionized or filtered water is non-negotiable here. For dry samples, weigh out 0.1 g to 1 g of powder (no more\u2014too much and you\u2019ll overload the sonicator, too little and statistics get wonky) and add it to 50 mL to 100 mL of dispersant. Stir by hand for 10 seconds first to get a rough slurry, so you don\u2019t have dry clumps floating around.<\/p>\n<p>Second step: Choosing the right sonicator. This is where as a supplier, we always tell customers not to buy the cheapest unit. A handheld sonicator for home brewing won\u2019t cut it for lab-grade disaggregation\u2014you need a unit with adjustable frequency, power, and an immersion probe (not a horn that sticks out, which can splash and lose energy). Wait, frequency vs. power: Low frequency (20 kHz) is more for breaking big, stubborn clumps (like 100+ micron agglomerates), while high frequency (40 kHz) is gentler, good for soft clumps (like 20-micron pigment clumps) that you don\u2019t want to break apart. Power is measured in watts\u2014for a 50 mL slurry, 10 W to 30 W is sweet spot; too much power (over 50 W) will heat up your sample, and heat can cause particles to agglomerate more or even alter your material (like sensitive pharmaceuticals). Also, get a sonicator with a temperature probe\u2014if your slurry goes above 40\u00b0C, turn the power down or pause to let it cool. We\u2019ve had customers run at full power and watch their slurry get so hot the dispersant evaporated, leaving hard clumps again. Oops.<\/p>\n<p>Third step: The actual disaggregation run. This is where you test incrementally, not just blast it for 5 minutes. Here\u2019s our go-to protocol: Start with a 10-second sonication burst. Turn the sonicator on, hold the probe 1 cm below the surface of the slurry (don\u2019t let it touch the bottom or sides of the container\u2014you\u2019ll get direct energy transfer that can damage both the probe and your particles, and create uneven disaggregation). Then take a tiny sample, run a quick laser size test, and check if the D50 (the median particle size) matches your expected value. If not, add another 10-second burst, and repeat. Wait\u201410 seconds? That\u2019s not a typo. If you sonicate for 2 minutes straight, you\u2019re going to start breaking actual primary particles, not just agglomerates. We\u2019ve seen this happen with a battery material customer who ran 2 minutes of ultrasound and went from a D50 of 15 microns to 8 microns\u2014turns out they were crushing the active material. So small, repeated bursts, not long runs. Also, if your sample has a lot of big clumps (over 100 microns), you can try a 20-second first burst, then back to 10s.<\/p>\n<p>Fourth step: Post-sonication checks. Don\u2019t just run your laser test right after sonication and call it done. Let the slurry sit for 1 minute, then gently swirl it to make sure any tiny settled particles are resuspended. Then, do a \u201crepeatability test\u201d \u2014 make 3 identical samples, disaggregate them the same way, and run size analysis. If the D50 varies more than 2%, you messed up the parameters (either too much power, not enough sonication, or inconsistent sample prep). We always tell customers that if their repeatability is off, go back to the power level\u20149 times out of 10, it\u2019s too high.<\/p>\n<p>Now, let\u2019s talk about common mistakes we see all the time, because even seasoned lab techs mess these up. First, using the wrong probe size. A big probe (10 mm) for a small 50 mL container means the energy is spread too wide, so you don\u2019t get enough focused sound to break clumps. A small probe (3 mm) for a 200 mL container means the energy is too concentrated, so it blasts too hard on one spot and not enough on the rest. Match the probe to your container: 3 mm for 25-100 mL, 6 mm for 100-500 mL, 10 mm for 500 mL+. Second, not degassing. Wait, degassing is before sonication\u2014take your slurry, put it in a vacuum chamber for 10 seconds to pull out any air bubbles. Air bubbles absorb ultrasound energy, so if you don\u2019t do this, your sound waves don\u2019t reach the particles, and you get uneven disaggregation. It\u2019s a tiny step, but it makes a huge difference. Third, using the same setup for every sample. A food powder and a ceramic powder have different agglomerate strengths\u2014you can\u2019t use 20 W for both. For soft organic materials, stick to 10-15 W; for hard mineral agglomerates, 20-25 W.<\/p>\n<p>Another thing: ultrasonic disaggregation vs. other sample prep methods. Why use this instead of, say, wet sieving or high-shear mixing? Wet sieving is good for big clumps, but it can miss small ones and takes forever. High-shear mixing is harsh, as we said, and can break particles. Ultrasound is gentle, fast (10 seconds vs. 5 minutes of mixing), and works for both dry and wet samples. For dry samples, you can even use a dry sonicator setup\u2014no liquid needed, just the probe in a closed container, which is perfect for powders that react with water (like certain metal powders). That\u2019s a niche but super useful use case we see a lot.<\/p>\n<p>Now, a quick note for the skeptics out there. We\u2019ve had customers who thought ultrasonic disaggregation was a gimmick\u2014until they ran a side-by-side test. One battery component lab used a high-shear mixer for their cathode powder, got a D50 of 22 microns, but after switching to our sonicator with 15 W and 4 10-second bursts, their D50 was 16 microns, which matched their manufacturing spec exactly. That\u2019s the kind of win that makes all the difference for quality control\u2014if your particle size is off, your battery capacity drops, and that\u2019s a big problem.<\/p>\n<p>So, when should you skip ultrasonic disaggregation? If your sample has real, irreversible aggregates (meaning the particles are stuck together with covalent bonds, not just weak van der Waals forces), this won\u2019t help. For example, sintered ceramic blocks\u2014you need to mill those, not sonicate. But 90% of the time, the samples we deal with have reversible agglomerates, so ultrasound is the way to go.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.fycgsonic.com\/uploads\/15823\/small\/3-in-1-recirculation-setup-with-flow-cell27e88.jpg\"><\/p>\n<p>If you\u2019re working on particle size analysis and your results just aren\u2019t lining up with what they should be, chances are ultrasonic disaggregation is the missing piece. We\u2019ve helped labs across industries tweak their setup, from academic research to industrial QC, and we know that getting the parameters right is half the battle. If you\u2019re ready to upgrade your sample prep and stop guessing at clumps skewing your data, let\u2019s connect to talk about what your specific samples need, no pressure\u2014just real advice from folks who do this every single day.<\/p>\n<p><a href=\"https:\/\/www.fycgsonic.com\/ultrasonic-sonochemistry-machine\/ultrasonic-cell-disruption\/\">Ultrasonic Cell Disruption<\/a> references<\/p>\n<ol>\n<li>ASTM Standard D4464-15, Standard Test Method for Particle Size Distribution of Catalytic Materials by Laser Light Scattering<\/li>\n<li>T. Allen, Particle Size Measurement, 7th Edition, John Wiley &amp; Sons, 2019<\/li>\n<li>K. G. Iller, The Chemistry of Silica: Solubility, Polymerization, Colloid and Surface Properties, and Biochemistry, John Wiley &amp; Sons, 1979<\/li>\n<li>S. E. Harding, A. J. Rowe, The Physical Chemistry of Biological Macromolecules, Royal Society of Chemistry, 2009<\/li>\n<li>Ultrasonic Disaggregation for Colloidal Systems, Journal of Colloid and Interface Science, Vol. 312, No. 2, 2007, pp. 457-464<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.fycgsonic.com\/\">Hangzhou Success Ultrasonic Equipment Co., Ltd.<\/a><br \/>Hangzhou Success Ultrasonic Equipment Co., Ltd. is one of the most professional ultrasonic disaggregation manufacturers and suppliers in China, certified by CE and ISO 9001. Feel free to contact our factory to buy ultrasonic disaggregation with high precision and competitive price here.<br \/>Address: No.209-3,Dalingshan Road,Dongzhou Street, Fuyang, Hangzhou, Zhejiang, China (Mainland)<br \/>E-mail: sales@fycg.com<br \/>WebSite: <a href=\"https:\/\/www.fycgsonic.com\/\">https:\/\/www.fycgsonic.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019re deep in the particle size analysis game, you know that sample prep is 90% &hellip; <a title=\"How to perform ultrasonic disaggregation for particle size analysis?\" class=\"hm-read-more\" href=\"http:\/\/www.deltafms.com\/blog\/2026\/11\/12\/how-to-perform-ultrasonic-disaggregation-for-particle-size-analysis-4ff4-2566ff\/\"><span class=\"screen-reader-text\">How to perform ultrasonic disaggregation for particle size analysis?<\/span>Read more<\/a><\/p>\n","protected":false},"author":58,"featured_media":768,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[731],"class_list":["post-768","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-ultrasonic-disaggregation-4a54-259f08"],"_links":{"self":[{"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/posts\/768","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/users\/58"}],"replies":[{"embeddable":true,"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/comments?post=768"}],"version-history":[{"count":0,"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/posts\/768\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/posts\/768"}],"wp:attachment":[{"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/media?parent=768"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/categories?post=768"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.deltafms.com\/blog\/wp-json\/wp\/v2\/tags?post=768"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}